Powerland’s solar mounting systems are built to safely and efficiently install your solar panels, ensuring they are positioned for maximum energy output while maintaining the structural integrity of your roof. We also offer a range of installation options, so please feel free to contact us today!
Solar Panel Fitting & Mounting Kits
Powerland Redtip Hookstop Single
Part No: RED-HOOKSTOP Mounting - Roof Flashings Plain tiles are notorious for breaking and can be quite expensive to replace, their fragility often results in such installations taking a longer amount of time to complete to avoid damaging the roof. This simple product negates this problem by allowing the roof hook to distribute the weight of the system (or installer) through the Hookstop and into the roof (as opposed to the weight being distributed directly onto one of the plain/rosemary tiles – resulting in damage). The Hookstop is an impact-absorbing pad designed made of recycled rubber, called Rypol, designed to replace individual roof tiles typically on a plain tile (rosemary) installation. You may have come across it on playgrounds and sports surfaces. “It completely eliminates the problem on Rosemary tiled roofs of installers standing on the mounting rail and the downward flexing of the roof hook, cracking the roof tile. Hookstop, prevents this by absorbing the roof hook flexing; it significantly speeds up installation time and the cost is largely offset because there is no lead work needed.” – an installer. Supplier Part No: RED-HOOKSTOP Weight: 0.53 kg
£6.02 Exc. VAT
£7.22 Inc. VAT
Powerland Genius Roof - Slate Refit Kit
Part No: GEN-SLATE Mounting - Roof Flashings The SolarFlash™ system is a simple and effective waterproof solution to refitting roofing slates or tiles around a roof bracket when installing solar photovoltaic, or other, panels. By installing with SolarFlash™, it can help you to ensure that all your installations are MCS 012 compliant. SolarFlash™ is very easy to install and enables you to do an excellent job and leave the roof with a clean, reliable and weatherproof finish, without any additional expert knowledge or training. Why you need SolarFlash™ The existing method of dressing a flashing material around the bracket is fundamentally flawed, as the bracket moves and in doing so can move the flashing material, which can potentially lead to damaged or cracked slates. This impacts on the weathertightness of the roof and means that the installation is not MCS 012 compliant. Parts included are: 1 x Large SolarFlash (364mm by 364mm) 1 x Weather stop Foam 2 x Shims 3 x Hallhooks 1 x Hookpull 3 x Compensation hooks Designer note: The Genius refit kits are compatible with most roof anchors but be aware a 30mm step up distance is required from the anchor fixing plate and the arm of the roof anchor. Generally this means anchors designed for plain tiles are most suited and certain products are not compatible.Non compatible components are: : SCH-256313, SCH-257125, SCH-256315, SLT-102001-000, SLT-102001-001, REN-920005. For any specific clarification, please let us know. Supplier Part No: SKI001 Weight: 0.34 kg
£7.19 Exc. VAT
£8.63 Inc. VAT
Powerland Genius Roof - Speed Flash
Part No: GEN-SPEEDFLASH Mounting - Roof Flashings The SpeedFlash® streamlines solar installations on slate roofs with a quick, no-‘drill through slate’ method that preserves roof integrity. Ideal for 18″+ slates, it minimizes the need for slate removal. Not for 4″ headlap composite slates. For use on all slate roofs with 3-inch head-lap 1 x SpeedFlash® Base and Cap 2 x Shims (packings) 1 x Foam Insert 1 x Spring support Unlike the SolarFlash®, you do not need to remove any slates. This significantly reduces installation time and the requirement for roofing experience. The SpeedFlash concept retains all the benefits of the SolarFlash®; i.e. no requirement for drilling, avoidance of load bearing and preventing water ingress, thereby maintaining the integrity of the roof. SpeedFlash Demonstration Video Supplier Part No: SPF005 Weight: 0.4 kg
£5.95 Exc. VAT
£7.14 Inc. VAT
Powerland Genius Roof - Interflash
Part No: GEN-INTERFLASH Mounting - Roof Flashings InterFlash™ Kit 1 x plastic InterFlash™ to sit under the Renusol RH Flat bracket. Supplier Part No: InterFlash Weight: 0.32 kg
£2.65 Exc. VAT
£3.18 Inc. VAT
Powerland Genius Roof - Speed Flash Shield
Part No: GEN-SPEEDFLASHSHIELD Mounting - Roof Flashings SpeedFlash® Shield is a tool that installers will need during installation to protect the lower course of slates. A SpeedFlash® Shield should last at least 40 SpeedFlash® installs, this will be determined by the user. The shields purpose is to protect the lower course of slates. Take care to avoid contact with angle grinder to prolong shield life. Supplier Part No: SPF008 Weight: 0.4 kg
£1.57 Exc. VAT
£1.88 Inc. VAT
Powerland Ubbink UBIFLEX B3 Non-Lead Flashing BLACK 400mm x 12m
Part No: UBIFLEX-B3-400X12 Mounting - Roof Flashings UBIFLEX NON-LEAD FLASHING BLACK 400mm x 12m Why use lead? Use Ubiflex instead! No scrap value – no risk of theft. Saves time & money – up to 50% quicker to install than lead. No toxic risk – environmentally friendly and recyclable. 80% lighter than lead – less risk of injury. BRE wind tunnel tested, BBA Certified and approved by NHBC (B3 only). 25 year guarantee (B3 only). Ubiflex Part No 534040 Supplier Part No: 534040 Weight: 18 kg
£214.88 Exc. VAT
£257.86 Inc. VAT
Powerland GSE/VELUX lateral Flashing for MK08 (Right) 2020 ONLY
Part No: GSE-VELUX-MK08-RIGHT Mounting - Roof Flashings GSE/VELUX lateral Flashing for MK08 (Right) Supplier Part No: ART103629 Weight: 0.57 kg
£31.75 Exc. VAT
£38.10 Inc. VAT
Powerland GSE/VELUX lateral Flashing for MK08 (Left) 2020 ONLY
Part No: GSE-VELUX-MK08-LEFT Mounting - Roof Flashings GSE/VELUX lateral Flashing for MK08 (Left) Supplier Part No: ART103622 Weight: 0.57 kg
£31.75 Exc. VAT
£38.10 Inc. VAT
Powerland Dektite Fixing Kit ( metal roof )
Part No: DFK1 Mounting - Roof Flashings Kit for fixing Dektites on metal roofs. Contains 25 screws/washers/caps + silicone sealant. One kit fixes 2 or 3 x Dektite DFE101BM Keywords: Deks, PV Cable, Cable Flashing Supplier Part No: FX901 Weight: 0.31 kg
£8.28 Exc. VAT
£9.94 Inc. VAT
Powerland Ubbink UBIFLEX high Tack Sealant
Part No: UBIFLEX-HIGH-TACK-SEALANT Mounting - Roof Flashings Ubiflex High Tack sealant for sealing Ubiflex down to tiles, slates and overlap joints. Ubbink Part no; 534066 Supplier Part No: 534066 Weight: 0.53 kg
£7.94 Exc. VAT
£9.53 Inc. VAT
Powerland Genius Roof - Hallhooks for Fitting Slates (10 Pack)
Part No: GEN-SLATE-HOOKS Mounting - Roof Flashings The Hallhook™ from Genius Roof Solutions is a permanent, secret and fail safe device that should be used when replacing a broken slate. The Hallhook was invented by a slater and tiler with 45 years of trade under his belt who couldn't stand to see a slate tiled roof covered with unsightly lead or copper straps. He tried all other available slate repairs such as straps, blobs of silicone, plastic proucts that are not only unsightly but time-consuming to install, etc. and then went on to develop the Hallhook. When to use the Hallhook™ For general repair After solar panel bracket mounting After roof light/window installation After installing slate vents This is a pack of 10 pcs. Supplier Part No:HHK001 Items in this pack:10 Weight:0.14 kg
£7.62 Exc. VAT
£9.14 Inc. VAT
Powerland Genius Roof - Flat Tiled Kit
Part No: GEN-FT-TILE Mounting - Roof Flashings The SolarFlash™ system is a simple and effective waterproof solution to refitting roofing slates or tiles around a roof bracket when installing solar photovoltaic, or other, panels. By installing with SolarFlash™, it can help you to ensure that all your installations are MCS 012 compliant. SolarFlash™ is very easy to install and enables you to do an excellent job and leave the roof with a clean, reliable and weatherproof finish, without any additional expert knowledge or training. Why you need SolarFlash™ The existing method of dressing a flashing material around the bracket is fundamentally flawed, as the bracket moves and in doing so can move the flashing material, which can potentially lead to damaged or cracked slates. This impacts on the weathertightness of the roof and means that the installation is not MCS 012 compliant. Parts included are: 1 x Small SolarFlash (H 235mm by W 251mm) 1 x Weather stop foam 2 x Shims Designer note: The Genius refit kits are compatible with most roof anchors but be aware a 30mm step up distance is required from the anchor fixing plate and the arm of the roof anchor. Generally this means anchors designed for plain tiles are most suited and certain products are not compatible. Non compatible components are: SCH-256313, SCH-257125, SCH-256315, SLT-102001-000, SLT-102001-001, REN-920005. For any specific clarification, please let us know. Supplier Part No: SFS003 Weight: 0.16 kg
£3.10 Exc. VAT
£3.72 Inc. VAT
Powerland Genius Roof - Slate Kit for New Build
Part No: GEN-SLATE-NEW Mounting - Roof Flashings The SolarFlash™ system is a simple and effective waterproof solution to refitting roofing slates or tiles around a roof bracket when installing solar photovoltaic, or other, panels. By installing with SolarFlash™, it can help you to ensure that all your installations are MCS 012 compliant. SolarFlash™ is very easy to install and enables you to do an excellent job and leave the roof with a clean, reliable and weatherproof finish, without any additional expert knowledge or training. Why you need SolarFlash™ The existing method of dressing a flashing material around the bracket is fundamentally flawed, as the bracket moves and in doing so can move the flashing material, which can potentially lead to damaged or cracked slates. This impacts on the weathertightness of the roof and means that the installation is not MCS 012 compliant. Parts included are: 1 x Large SolarFlash (364mm by 364mm) 1 x Weather stop Foam 2 x Shims Designer note: The Genius refit kits are compatible with most roof anchors but be aware a 30mm step up distance is required from the anchor fixing plate and the arm of the roof anchor. Generally this means anchors designed for plain tiles are most suited and certain products are not compatible.Non compatible components are: : SCH-256313, SCH-257125, SCH-256315, SLT-102001-000, SLT-102001-001, REN-920005. Supplier Part No: SFS001 Weight: 0.24 kg
£3.30 Exc. VAT
£3.96 Inc. VAT
Powerland Deks Fast Flash 280mm x 5m Roll - Black
Part No: FFLASH-5280B Mounting - Roof Flashings Fast Flash is a self adhesive lead replacement material that has many uses beyond replacement for traditional lead. Fast Flash can be used to flash large round or square penetrations that a Dektite cannot cover - with its self adhesive backing you'll have a water tight penetration in minutes! This part can be used on GSE In-Roof or Easy Roof In Roof systems as a sealing strip replacement. It can be used to provide a continuous waterproof border along the bottom edge of the PV array. It can also be used for the top edge of the array instead of upper metal flashing components. Supplier Part No:FFR5280B Weight:4.5 kg
£88.74 Exc. VAT
£106.49 Inc. VAT
Powerland Deks Fast Flash 370mm x 5m Roll - Black
Part No: FFLASH-5370B Mounting - Roof Flashings Fast Flash is a self adhesive lead replacement material that has many uses beyond replacement for traditional lead. Fast Flash can be used to flash large round or square penetrations that a Dektite cannot cover - with its self adhesive backing you'll have a water tight penetration in minutes! This part can be used on GSE In-Roof or Easy Roof In Roof systems as a sealing strip replacement. It can be used to provide a continuous waterproof border along the bottom edge of the PV array. It can also be used for the top edge of the array instead of upper metal flashing components. Supplier Part No:FFR5-370B Weight:5.9 kg
£117.13 Exc. VAT
£140.56 Inc. VAT