Powerland is a proud dealer of Victron Energy products, offering a comprehensive selection for off-grid, marine, and mobile applications. From inverters to solar chargers, Victron is known for its reliability and innovation.
Victron
Victron Victron Energy Skylla-IP65 24/35(1+1) 120-240V – SKY024035000
The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air. Features Skylla-IP65 (1+1): two outputs to charge 2 battery banks The Skylla-IP65 (1+1) features 2 isolated outputs. The second output, limited to approximately 3 A and with a slightly lower output voltage, is intended to top up a starter battery IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY024035000 GTIN 8719076051985 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 12A Charge current 35A Charge current starter batt. 3A Charge Algorithm 7 stage adaptive Battery Capacity 150-350Ah Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off Yes (can be connected to a Li-Ion BMS) CAN-bus communication port (VE.Can) Two RJ45 connectors, NMEA2000 protocol, not isolated Synchronised Parallel Operation Yes, with VE.Can Battery-Connection M6 bolts Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years
£429.90 Exc. VAT
£515.88 Inc. VAT
Victron Victron Energy Skylla-TG 24/30(1+1) – SDTG2400301
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400301 Voltage 24 Charger Current House Battery 30A Charger Current Starter Battery 4A Recommended Battery Capacity 150 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D147mm Weight (kg) 5.5 Warranty 5 Years
£473.90 Exc. VAT
£568.68 Inc. VAT
Victron Victron Energy Skylla-TG 24/50(1+1) – SDTG2400501
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400501 Voltage 24 Charger Current House Battery 50A Charger Current Starter Battery 4A Recommended Battery Capacity 150 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D147mm Weight (kg) 5.5 Warranty 5 Years Country of Manufacture Malaysia
£512.50 Exc. VAT
£615.00 Inc. VAT
Victron Victron Energy Skylla-IP65 12/70(1+1) – SKY012070000
The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air. Features Skylla-IP65 (1+1): two outputs to charge 2 battery banks The Skylla-IP65 (1+1) features 2 isolated outputs. The second output, limited to approximately 3 A and with a slightly lower output voltage, is intended to top up a starter battery IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY012070000 GTIN 8719076051961 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 VAC 12A Charge current 70A Charge Algorithm 7 stage adaptive Battery Capacity 350-700Ah Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off port Yes (can be connected to a Li-Ion BMS) Battery-Connection M6 bolts 230 VAC-connection Screw-clamp 6mm² (AWG 10) Protection Category IP65 Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years
£529.90 Exc. VAT
£635.88 Inc. VAT
Victron Victron Energy Skylla-TG 24/30(1+1) GL – SDTG2400303
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400303 Voltage 24 Charger Current House Battery 30A Charger Current Starter Battery 4A Recommended Battery Capacity 150 – 300Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x D250 x D147mm Weight (kg) 5.5 Warranty 5 Years
£578.90 Exc. VAT
£694.68 Inc. VAT
Victron Victron Energy Skylla-IP65 12/70(3) 120-240V – SKY012070100
The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air. Features Skylla-IP65 (3): three full current outputs to charge 3 battery banks The Skylla-IP65 (3) features 3 isolated outputs. All outputs can supply the full rated output current. IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY012070100 GTIN 8719076051978 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 12A Charge current 3 x 70A Charge current starter batt. n.a Charge Algorithm 7 stage adaptive Battery Capacity 350-700Ah Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off Yes (can be connected to a Li-Ion BMS) CAN-bus communication port (VE.Can) Two RJ45 connectors, NMEA2000 protocol, not isolated Synchronised Parallel Operation Yes, with VE.Can Battery-Connection M6 bolts Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years
£583.80 Exc. VAT
£700.56 Inc. VAT
Victron Victron Energy Skylla-IP65 24/35(3) 120-240V – SKY024035100
The IP65 rating makes this charger especially suitable for marine, mobile, and industrial applications and it can withstand the rigors of an adverse environment: heat, humidity and salt air. Features Skylla-IP65 (3): three full current outputs to charge 3 battery banks The Skylla-IP65 (3) features 3 isolated outputs. All outputs can supply the full rated output current. IP65 protection Steel epoxy powder coated case. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. LCD display For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use. CAN-bus interface (NMEA2000) To connect to a CAN-bus network, to a Skylla-i Control panel or to the Color Control digital display. Synchronised parallel operation Several chargers can be connected in parallel and synchronised with help of the CAN-bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP65 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-IP65 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-IP65 is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Use as a power supply As a result of the excellent control circuit, the Skylla-IP65 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN-bus port. Brand Victron Energy Manufacturer Part Number SKY024035100 Input Voltage 120/230V Input Voltage Range 90-265V Maximum AC input current @ 100 12A Charge current 3 x 35A Charge current starter batt. n.a Charge Algorithm 7 stage adaptive Battery Capacity 150-350Ah Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control Temperature Sensor Yes Can Be Used As Power Supply Yes Remote on-off Yes (can be connected to a Li-Ion BMS) CAN-bus communication port (VE.Can) Two RJ45 connectors, NMEA2000 protocol, not isolated Synchronised Parallel Operation Yes, with VE.Can Battery-Connection M6 bolts Dimensions H401 x W265 x D151mm Weight 6Kg Warranty 5 Years Country of Manufacture Malaysia
£583.80 Exc. VAT
£700.56 Inc. VAT
Victron Victron Energy Skylla-TG 48/25(1) – SDTG4800251
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG4800251 Voltage 48 Charger Current House Battery 25A Charger Current Starter Battery N.A. Recommended Battery Capacity 125 – 250Ah Battery Connection M8 Studs Outputs 1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D147mm Weight (kg) 5.5 Warranty 5 Years
£616.00 Exc. VAT
£739.20 Inc. VAT
Victron Victron Energy Skylla-TG 24/50(1+1) GL – SDTG2400503
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400503 Voltage 24 Charger Current House Battery 50A Charger Current Starter Battery 4A Recommended Battery Capacity 250 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x D250 x 147mm Weight (kg) 5.5 Warranty 5 Years
£625.80 Exc. VAT
£750.96 Inc. VAT
Victron Victron Energy Skylla-TG 24/30 GMDSS – SDTG2400302
Features GMDSS The Global Maritime Distress & Safety System (GMDSS) was developed by the International Maritime Organisation (IMO) to improve maritime distress and safety communications. Power supply The Skylla TG has proven itself to be an excellent battery charger and power supply for GMDSS applications. However, when using a standard Skylla Charger, additional equipment is needed to perform the monitoring and alarm functions required for GMDSS. Installation made easy: the Skylla GMDSS The Victron Skylla GMDSS Charger has been designed to provide all required monitoring and alarm data. Both the battery and the GMDSS system are connected directly to the charger. Data and alarms are displayed on a digital panel (VE.Net GMDSS panel, to be ordered separately). A standard eight wire UTP-cable connects the charger to the panel. No adjustments needed The whole system is ‘click and go’: the panels are pre-programmed for GMDSS functionality. A simple, intuitive menu allows changing of settings if required. Battery time to go The Skylla GMDSS charger has a built-in battery controller. The capacity of the battery is fully monitored so the panel can even indicate the ’time to go’ in case of a power supply black out. Perfect charger for any type of battery Charge voltage can be precisely adjusted to suit any VRLA or flooded battery system Brand Victron Energy Manufacturer Part Number SDTG2400302 Voltage 24 Charge Current (A) 30 (limited to 22A at 110VAC) Input Voltage 230VAC Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H485 x W250 x D147mm Weight (kg) 6 Warranty 5 Years
£700.00 Exc. VAT
£840.00 Inc. VAT
Victron Victron Energy Skylla-i 24/80(1+1) – SKI024080000
The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024080000 Voltage 24 Charger Current House Battery 80A Charger Current Starter Battery 4A Recommended Battery Capacity 400 – 800Ah Battery Connection M8 Bolts Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years
£805.00 Exc. VAT
£966.00 Inc. VAT
Victron Victron Energy Skylla-TG 24/80(1+1) – SDTG2400801
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2400801 Voltage 24 Charger Current House Battery 80A Charger Current Starter Battery 4A Recommended Battery Capacity 400 – 800Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years
£840.70 Exc. VAT
£1,008.84 Inc. VAT
Victron Victron Energy Skylla-TG 24/50(1+1) 3 Phase – STG024050300
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number STG024050300 Voltage 24 Charger Current House Battery 50A Charger Current Starter Battery 4A Recommended Battery Capacity 250 – 500Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 13 Warranty 5 Years
£895.00 Exc. VAT
£1,074.00 Inc. VAT
Victron Victron Energy Skylla-i 24/80(3) – SKI024080002
The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024080002 Voltage 24 Charger Current House Battery 3 x 80A Charger Current Starter Battery N.A. Recommended Battery Capacity 400 – 800Ah Battery Connection M8 Bolts Outputs 3 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years
£938.70 Exc. VAT
£1,126.44 Inc. VAT
Victron Victron Energy Skylla-TG 24/50 GMDSS – SDTG2400504
Features GMDSS The Global Maritime Distress & Safety System (GMDSS) was developed by the International Maritime Organisation (IMO) to improve maritime distress and safety communications. Power supply The Skylla TG has proven itself to be an excellent battery charger and power supply for GMDSS applications. However, when using a standard Skylla Charger, additional equipment is needed to perform the monitoring and alarm functions required for GMDSS. Installation made easy: the Skylla GMDSS The Victron Skylla GMDSS Charger has been designed to provide all required monitoring and alarm data. Both the battery and the GMDSS system are connected directly to the charger. Data and alarms are displayed on a digital panel (VE.Net GMDSS panel, to be ordered separately). A standard eight wire UTP-cable connects the charger to the panel. No adjustments needed The whole system is ‘click and go’: the panels are pre-programmed for GMDSS functionality. A simple, intuitive menu allows changing of settings if required. Battery time to go The Skylla GMDSS charger has a built-in battery controller. The capacity of the battery is fully monitored so the panel can even indicate the ’time to go’ in case of a power supply black out. Perfect charger for any type of battery Charge voltage can be precisely adjusted to suit any VRLA or flooded battery system Brand Victron Energy Manufacturer Part Number SDTG2400302 Voltage 24 Charge Current (A) 30 (limited to 22A at 110VAC) Input Voltage 230VAC Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H485 x W250 x D147mm Weight (kg) 6 Warranty 5 Years
£949.17 Exc. VAT
£1,139.00 Inc. VAT
Victron Victron Energy Skylla-i 24/100(1+1) – SKI024100000
The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024100000 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Bolts Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years
£972.30 Exc. VAT
£1,166.76 Inc. VAT
Victron Victron Energy Skylla-TG 24/100(1+1) – SDTG2401001
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2401001 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years
£1,015.00 Exc. VAT
£1,218.00 Inc. VAT
Victron Victron Energy Skylla-i 24/100(3) – SKI024100002
The right amount of charge for a lead-acid battery: variable absorption time BatterySafe mode: preventing damage due to excessive gassing Storage mode: less maintenance and aging when the battery is not in use Smaller and lighter compared to similar models NMEA2000 Canbus connection PowerControl: set a maximum shore power Remote Control Li-ion (LiFePo4) ready Features Rugged Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Flexible Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. Synchronised parallel operation Several chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Please see the manual for details. The right amount of charge for a lead-acid battery: variable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. Preventing damage due to excessive gassing: the BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. Less maintenance and aging when the battery is not in use: the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure. To increase battery life: temperature compensation Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected. Battery voltage sense In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage. Suitable for AC and DC supply (AC-DC and DC-DC operation) The chargers also accept a DC supply. Use as a power supply As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available. Li-Ion (LiFePO4) ready Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. Brand Victron Energy Manufacturer Part Number SKI024100002 Voltage 24 Charger Current House Battery 3 x 100A Charger Current Starter Battery N.A. Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Bolts Outputs 3 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H405 x W250 x D150mm Weight (kg) 7 Warranty 5 Years
£1,139.60 Exc. VAT
£1,367.52 Inc. VAT
Victron Victron Energy Skylla-TG 48/50(1) – SDTG4800501
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG4800501 Voltage 48 Charger Current House Battery 50A Charger Current Starter Battery N.A. Recommended Battery Capacity 250 – 500Ah Battery Connection M8 Studs Outputs 1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years
£1,172.00 Exc. VAT
£1,406.40 Inc. VAT
Victron Victron Energy Skylla-TG 24/100(1+1) GL – SDTG2401003
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number SDTG2401003 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H365 x W250 x D257mm Weight (kg) 10 Warranty 5 Years
£1,175.00 Exc. VAT
£1,410.00 Inc. VAT
Victron Victron Energy Skylla-TG 24/100(1+1) 3 Phase – STG024100300
Features Perfect chargers for any type of battery Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail. Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3-phase input models, the chargers also accept a DC supply. Controlled charging Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes. Use of TG Chargers as a power supply As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available. Two outputs to charge 2 battery banks (24V models only) The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. To increase battery life: temperature compensation Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting. Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage. Brand Victron Energy Manufacturer Part Number STG024100300 Voltage 24 Charger Current House Battery 100A Charger Current Starter Battery 4A Recommended Battery Capacity 500 – 1000Ah Battery Connection M8 Studs Outputs 1+1 Temperature Sensor Yes Can Be Used As Power Supply Yes IP Rating IP21 Dimensions H515 x W260 x D265mm Weight (kg) 23 Warranty 5 Years
£1,555.50 Exc. VAT
£1,866.60 Inc. VAT